The steps
- Turn everything off, shut the doors and set the meter to amps.
- Bridge the battery − post and the − cable clamp with the ammeter, then lift the clamp off the post. All the current now flows through the meter.
- Wait for the modules to sleep without opening a door.
- Compare the draw with the limit. If it is over, pull fuses one at a time, without putting them back, and watch the meter. The fuse that brings the draw under the limit names the circuit.